7. Reference SNR Calibration
This chapter is optional. Use it when a measured receiving-chain offset should be removed from an antenna comparison. If the receivers or complete stations are what you want to compare, that difference may be part of the result. Keep No correction unless a documented calibration justifies a correction.
This RX procedure does not establish a TX correction. An SNR correction does not change decode counts or ΔDecode.
Goal: establish a stable reported-SNR offset between two receive chains supplied from a common input, then validate it independently. Decide what the experiment should correct: unequal downstream receive chains may need correction when comparing antennas; subtracting that difference when the receivers themselves are under test could remove the result being measured. A shared-antenna example appears in [Ref-2].
This receiver-splitter procedure does not establish a TX correction. TX needs an independently established basis appropriate to its transmit paths and truthful power reports; see Section 9.2.2.
- Define the calibration boundary. Record the reference plane: the corresponding connection point in each chain where the common input is applied. List the downstream cables, filters, amplifiers, receiver and decoder settings. Keep each exact Target or Reference reporting identity attached to its documented physical chain.
- Provide a common input. Feed both chains simultaneously from one stable antenna through a suitable splitter and controlled cables. Characterize output imbalance and cable differences, and record the feed-arm assignments. Nominal splitter loss alone is not an SNR correction.
- Collect uncorrected evidence. In RX Benchmark, choose Reference SNR correction → No correction, which applies 0.0 dB. Verify simultaneous reception and uploads, then collect pairs on the intended band across relevant signal levels with unchanged gain, filtering and decoder settings. When practical, also record a control run with the splitter feed arms exchanged, keeping identities with their receiver chains.
- Choose and record the summary. Use the ΔSNR summaries in Benchmark Statistics for the documented calibration period, filters and scope. Record both statistic and weighting: the median of station-median ΔSNR and the mean of station-mean ΔSNR give every included station equal weight; a pooled median or mean of qualifying spot pairs gives every included pair equal weight. Record station and pair counts and use the same summary definition for validation. WSPRadar does not determine the correction automatically.
- Check that one constant is justified. Inspect differences by station, time and SNR, and across the frequencies and settings where the correction will be used. Investigate a difference that follows the splitter feed arm. A constant is not defensible if it changes materially with level, frequency, AGC, equipment state or time. Resolve fixture imbalance, clipping, unstable gain or intermittent routing, and recheck after changes to the calibrated setup.
- Apply the sign. Choose Use a documented correction and enter the value in Reference-side SNR correction (dB). For an uncorrected Target-minus-Reference offset of +1.6 dB, enter +1.6 dB: Reference SNR rises and ΔSNR falls by 1.6 dB. Enter a negative offset with its negative sign. A documented 0.0 dB remains distinct from No correction. Correction changes ΔSNR, not decode counts, ΔDecode or raw cumulative-SNR curves.
- Validate with new evidence. Keep the correction fixed and collect a separate common-input period with the same chain definitions and settings. Check for a corrected summary plausibly near zero and consistency across stations, time and SNR; record residual offset and variation. Zero obtained from the same observations used to estimate the offset is not independent validation. Keep identities with their chains during feed-arm exchanges. If only the Target and Reference roles of the same calibrated chains are exchanged, negate the correction and update the identity mapping.
Ready to proceed: the fixture checks support the comparison, the offset is stable for the intended conditions, and separate validation supports using it. Reconnect the experimental inputs at the recorded reference planes, preserve the calibrated chains and settings, then return to Section 1.2.
Calibration record: keep exact identities and physical-chain mapping; band, reference plane, settings and splitter/cable assignments; calibration periods, filters and scope; statistic, weighting and station/pair counts; estimated offset, applied signed value and independent validation residuals. Save the uncorrected, optional feed-arm-control and validation runs separately. Section 10.3 gives the full experiment record.
Repeatability supports one additive offset within the tested arrangement, not traceable laboratory accuracy. Splitter loss, mismatch, coupling, cable effects and source instability can remain. A geographically separate Reference can provide a repeatable baseline for that pair, band and setup, but not this common-input calibration or an absolute calibration.