Documentation

5. Set up an RX Benchmark

Receive the same WSPR transmissions simultaneously through two independent paths, called Target and Reference. Start on one band with band hopping off. This is the simplest starting arrangement, not a restriction of WSPRadar.

For a simultaneous TX experiment, use Chapter 6. The scheduling explanation in Chapter 6 explains why matching two WSJT-X Tx Pct settings does not establish a shared schedule that uses only some transmit cycles.

5.1 Two receivers and two computers

If two computers are available, this avoids the extra setup for multiple instances. Each computer uses its normal WSJT-X configuration and local files.

  1. Connect each antenna and receiver to its own computer. In WSJT-X, select that receiver’s audio input and CAT connection. If CAT is unnecessary, select None and tune the receiver manually to the correct WSPR USB dial frequency.
  2. In File > Settings > General, enter a different reporting identity in My Call for each path and its truthful locator in My Grid. With one base callsign, RX reporting labels such as CALL/1 and CALL/2 can distinguish the paths; replace CALL and verify that the reporting service retains both exact identities. These internet reporting labels do not establish valid on-air TX callsigns.
  3. Select Mode > WSPR and the same band on both. Check the audio level and decoder settings. Keep receiver gain, filtering and decoder settings stable and record any differences between the chains.
  4. Check UTC synchronization with NetTime on both computers as described above. Start Monitor, keep Enable Tx off, and enable Upload spots on both. Prevent either computer from sleeping during the run.
  5. Before measuring, temporarily change or disconnect one receive input at a time. Confirm that only the intended decoder responds. Exclude these routing checks from the measurement period.
  6. Confirm that both exact identities appear in the database selected in WSPRadar and that both report some of the same transmitted messages in the same two-minute cycles. Allow for upload delay. Start a fresh comparison window once both paths work.

No connection between the two computers is needed for the comparison; each needs its own normal route for uploading reports. Continue with the RX Benchmark playbook in Section 2.1. Keep No correction unless Chapter 7 provides a documented reason to change it. [Ref-11]

5.2 Two receivers and one Windows computer

Goal: run two receive paths at the same time, with separate audio inputs, reporting callsigns, settings and files. This Windows procedure uses WSJT-X's documented --rig-name option; it does not require a second installation of WSJT-X [Ref-11].

Create two named instances: WSJT-X Target and WSJT-X Reference. Optionally copy a working starting configuration, then check both paths before collecting measurements. These names identify the local software instances; they do not set the callsigns uploaded to the database.

Configuration cloning is optional. NetTime runs once for this computer, not once per WSJT-X instance. Complete the same routing and public-report checks as for two computers.

5.2.1 Create the Target and Reference instances
  1. Create two desktop shortcuts for your installed wsjtx.exe. Name them WSJT-X Target and WSJT-X Reference.
  2. Open each shortcut's Properties. In the Windows Target field, add its rig name after the executable's closing quotation mark. Replace the example executable path with your installation path:
Shortcut Windows shortcut Target field
WSJT-X Target "C:\WSJTX\bin\wsjtx.exe" --rig-name=Target
WSJT-X Reference "C:\WSJTX\bin\wsjtx.exe" --rig-name=Reference
  1. Start each shortcut once, then close it to initialize its files.

The Windows locations are:

File or folder WSJT-X Target WSJT-X Reference
Settings %LOCALAPPDATA%\WSJT-X - Target\WSJT-X - Target.ini %LOCALAPPDATA%\WSJT-X - Reference\WSJT-X - Reference.ini
Logs and writable files %LOCALAPPDATA%\WSJT-X - Target\ %LOCALAPPDATA%\WSJT-X - Reference\
Default saved audio %LOCALAPPDATA%\WSJT-X - Target\save\ %LOCALAPPDATA%\WSJT-X - Reference\save\

Open these folders in File Explorer: press Windows+E, then Ctrl+L to select the address bar. Type %LOCALAPPDATA% and press Enter to open your user account's local application-data folder. Open WSJT-X - Target or WSJT-X - Reference. You can also paste a complete folder path from the table into the address bar. You do not need to enable Hidden items.

Always launch the two instances with their named shortcuts. A different rig name creates a different set of locations. If your WSJT-X version uses different menus or paths, check its matching user guide [Ref-11].

5.2.2 Clone the starting configuration if required

Optional: configure WSJT-X Target first using 5.3, then copy its configuration so WSJT-X Reference starts with the same settings. Otherwise configure both instances directly in 5.3.

  1. Close all WSJT-X instances and retain a backup of any settings you intend to replace.
  2. Copy the Target settings file %LOCALAPPDATA%\WSJT-X - Target\WSJT-X - Target.ini into the Reference folder %LOCALAPPDATA%\WSJT-X - Reference\.
  3. Rename the copy to WSJT-X - Reference.ini, replacing the newly initialized Reference file only if that is your intention.

The resulting Reference settings file must be %LOCALAPPDATA%\WSJT-X - Reference\WSJT-X - Reference.ini. Cloning also copies hardware, directory and station settings; complete every applicable check below on both instances before starting reception.

Reusing an existing configuration: you can first seed WSJT-X Target with the settings you already use, following the same close, back up, copy and rename procedure. For an existing default configuration, the source file is %LOCALAPPDATA%\WSJT-X\WSJT-X.ini; copy it into the Target folder and name it WSJT-X - Target.ini. You can then clone Target to Reference as above.

Separate instance file locations

These local directory settings apply when both named instances share one Windows computer. Check them separately after cloning.

Check What to set or verify
Saved audio Set Save Directory to %LOCALAPPDATA%\WSJT-X - Target\save\ for Target and %LOCALAPPDATA%\WSJT-X - Reference\save\ for Reference.
AzEl output, if used Give AzEl Directory its own location: %LOCALAPPDATA%\WSJT-X - Target\ for Target and %LOCALAPPDATA%\WSJT-X - Reference\ for Reference. This output is used by the Astronomical Data feature; it is not required for WSPR analysis.

5.3 Check both receive paths

Open each WSJT-X configuration in turn and check the following for its respective physical path. On one Windows computer, these are WSJT-X Target and WSJT-X Reference. A copied configuration can still select the Target's audio or radio in the Reference instance.

Check What to set or verify
Audio input In File > Settings > Audio, select the intended receiver's Input. If independent paths share a stereo audio interface, select the correct channel for each instance.
Audio format Configure the Windows audio device for 48 000 Hz, 16-bit sampling, as specified by the WSJT-X guide. Disable Windows audio enhancements for these devices.
Radio control In File > Settings > Radio, use the intended radio and control connection. Select None when this audio-only setup does not need CAT control, and manually tune the receiver or SDR to the matching WSPR USB dial frequency.
Reporting identity In File > Settings > General, enter each instance's exact reporting identity in My Call and that receiver setup's truthful locator in My Grid. Use the two-callsign or one-callsign choice below; the identities must remain distinguishable in the database.
WSPR operation Select Mode > WSPR and the intended band, enable Monitor, check the audio level and decoder settings, leave Enable Tx off for this RX experiment, and enable spot uploading.
Time Check that the computer is synchronized to UTC within ±1 second. Instances on the same PC share its clock; separate PCs each need synchronization. Use the shared Windows timing check.

These settings and the instance-specific paths follow the WSJT-X guide [Ref-11].

Choose the RX reporting identities. If two appropriate callsigns are available, use one for each receive path. With one base callsign, use two distinct reporting suffixes, for example CALL/1 for Target and CALL/2 for Reference. Replace CALL with your actual base callsign and confirm that the reporting service accepts and retains both exact identities. Enter each receiver's actual locator; colocated setups normally share it, while receivers at different sites retain their own locations.

WSJT-X sends the receiver's reporting identity over the internet with each uploaded spot. A suffix here does not change the remote transmitter's WSPR message and does not require extra on-air transmissions. Keep Enable Tx off for this RX setup. For an on-air compound callsign, use the TX route in Section 6.1.2; acceptance of an RX reporting label does not establish its validity for transmission [Ref-11].

Ready to measure

Both independent paths are receiving on the intended band, with correct clocks, stable settings and distinct reporting identities visible in the selected database. The complete RX settings checklist applies to both routes, with local file separation needed only when sharing one computer.

Ready for an RX test: both instances receive the intended independent streams and upload under the correct identities on the selected band. Confirm the hardware routing empirically; separate folders alone do not prove separate RF paths. Check that the reports reach the database selected in WSPRadar, allowing for upstream delay.

If the comparison needs a measured receiving-chain correction, continue with Chapter 7. Otherwise use the RX Benchmark procedure with the documented setup.