Documentation

11. Controls and Configuration

Changing the analysis type, station callsigns or locators, band, UTC window, Reference correction, filters or evidence requirements clears the completed result and requires a new Run. Changing an Inspector selection, station-list filter, time aggregation, time basis or Drill-Down view does not rerun the analysis. In Performance, changing Shared confidence level updates the temporal mean intervals in the completed result. In Benchmark, that setting requires a new run.

11.1 Workflow controls

Control What you need to know
Input view Guided and Compact use the same analysis settings. Your selected input view stays selected for the session and is not stored in saved configurations.
Load Demo Loads settings without running and keeps your selected Guided or Compact view. Load and walk through setup opens the progressive Guided steps or the complete Compact editor at its first setup panel; Load and review to run opens that view's Review directly. In Guided, the collapsed Guided demo panel retains the experiment notes and the Walk me through the setup / Skip to review navigation actions. Only Run RX Analysis or Run TX Analysis starts the analysis.
Start Fresh Clears settings and results and restores defaults, including the UTC window. Language and input view stay unchanged.
Load Config / Save Config Load or save applicable analysis settings and supported view choices. Saved dates are fixed UTC boundaries, not a rolling period. A configuration contains no result data or station notes.
Run RX Analysis / Run TX Analysis Starts the chosen analysis after validation. Resolve highlighted fields and any Reference location choice first. A map can appear before the remaining views are ready; wait for Complete.
Prepare All Results for Download Builds the export for the current selections. Then choose Download Prepared Results. Prepare again after changing the selections. See export contents.

After a run, an edit that clears the completed result reopens a collapsed Review panel in Guided or Compact once the settings are valid. Under RUN ANALYSIS, the panel shows Save Config and the Run button for the selected direction. For Benchmark, the operating-conditions explanation and checkbox appear directly above these buttons. You can reach Review and save otherwise valid settings while the box is unchecked. Starting a Benchmark requires checking the box.

Keyboard: use Tab and Shift+Tab to move between controls. In Guided, forward Tab beyond a setup panel validates it and opens the next step, like Continue; errors return focus to the first invalid field. Reaching Review does not start the analysis. The separate ? help icons require a pointer.

Loading or saving a configuration does not run it. Unsupported old formats are rejected. One compatibility exception accepts a complete valid pair of former ΔDecode count thresholds and replaces them with the 1% event-share default, with a notice; it does not convert counts into percentages. Review loaded settings before running.

11.2 Question, Target and measurement-window controls

Control Default and essential rules
Question Required: choose RX Performance, TX Performance, RX Benchmark or TX Benchmark. Only Benchmark needs a Reference.
Target callsign Required. In RX, use Target callsign (receiver under test). In TX, use Target callsign (transmitter under test). Enter the callsign exactly as reported, including any prefix or suffix. CALL, CALL/P and CALL-1 are distinct reported callsigns.
Target Grid Locator (optional) Leave blank for discovery after Run analysis, or enter a valid four- or six-character Maidenhead locator. The empty field shows >auto-discover<. The first four locator characters select Target reports; the full entered or discovered locator anchors map, distance, direction and solar calculations.
Operating Band Default 20m. Select one band.
SNR TX Normalization to 30 dBm TX Performance only, to the right of Operating Band. Off for a new analysis: received SNR as reported. On: normalize using reported transmit power to 30 dBm (1 W). This is a scientific setting requiring an analysis rerun. Older settings without the field retain On. RX Performance and Benchmark remain normalized.
Start / End Date/Time (UTC) Default: 24 hours ending at the current UTC minute. Dates start in 2008; a run may span at most 31 elapsed days. Times retain minute precision.

New TX Performance analyses default to the raw reported-SNR basis. Saved TX Performance configurations and links explicitly preserve the on/off boolean tx_snr_normalization_to_30dbm: in configurations it is core_parameters.tx_snr_normalization_to_30dbm, and the URL parameter has the same field name. An older configuration, link or completed-run record that lacks the field retains normalization on, preserving its former interpretation. Explicit true/false choices survive save, link, load and completed-run restoration. The setting is active only for TX Performance; it does not change RX Performance or Benchmark. Changing the scientific basis requires an analysis rerun; the observations and cached results for the two settings are kept separate. A loaded old run is not silently reinterpreted as raw SNR.

A four-character Maidenhead locator (grid-4) identifies a grid square; six characters identify a smaller subsquare.

In Guided and Compact input, automatic location discovery starts only after Run analysis and uses the selected callsign, RX/TX direction, band and UTC window. Performance discovers the Target location; Benchmark looks up Target and Reference together when either required location is missing. One valid Target locator is selected automatically. Multiple full Target locators require your choice, including different six-character locators within the same grid-4; a selected six-character locator is not shortened. Reference choices use grid-4 and show the full reported variants. Choosing locations continues with the existing discovery results, without repeating the lookup. If no valid location is found, enter an independently known locator or revise the settings. Manually entered locators remain authoritative, and supplying all required locators skips discovery. A reported locator identifies a grid cell, not a verified antenna position.

11.3 Benchmark-design controls

Control What to enter
Reference callsign Enter the Reference callsign exactly as reported. It must differ from Target. Reference Neighborhood is no longer supported.
Reference Grid Locator (optional) Leave blank to discover the location from reports after Run analysis, or enter an independently known grid-4. The empty field shows >auto-discover<. One discovered grid resolves automatically; several require your choice. A known location does not establish operation.
Reference SNR correction Default No correction applies 0.0 dB. Choose Use a documented correction only for an established offset valid for this setup. The signed field accepts −99.9 to +99.9 dB; blank means 0.0. Use a decimal point. A documented zero remains distinct from no established correction.

Benchmark acceptance: every Benchmark run requires I have confirmed common operation, or accept the limitations when it is unverified. Check common operation as described in Section 1.2; when it is unverified, interpret the observations within the stated limitations. Changing station identities, direction or band clears acceptance. Changing the period also clears it, except when you select an eligible cycle-aligned subwindow of the completed acquisition with unchanged acquisition settings. In that case the chosen Reference site and existing acceptance carry over, and a new Run is still required. Loading a personal configuration or ordinary analysis link requires fresh acceptance; a saved acceptance does not verify operation.

The same acceptance applies to historical observations, including Milazzo; there is no separate historical mode. Ordinary analysis links require fresh acceptance, including links with the inert run=1 parameter. Opening a link never starts an analysis. Built-in demos preselect this acceptance; their experiment notes explain known operating conditions and uncertainties. A link selecting an installed demo opens Review directly with that demo selected, preserving your selected Guided or Compact view; a fresh session defaults to Guided. In Guided, its experiment notes remain available in the collapsed 00 Guided demo panel. This shortcut does not apply to ordinary shared-settings URLs, which still require fresh Benchmark acceptance. Loading a demo alone still does not run it.

Reference-side SNR correction sign

A positive correction raises Reference SNR and reduces ΔSNR. If a common-input calibration measured Target minus Reference as +1.6 dB, enter +1.6 dB. Correction does not change decode counts or raw cumulative-SNR curves. To collect a baseline, use No correction; WSPRadar does not determine an offset automatically. See Chapter 7 for calibration and its limits.

11.4 Filters and evidence thresholds

The values shown in Optional Filters, scope and evidence apply even when you leave that panel untouched. The table gives fresh-setup defaults; demos and loaded configurations use their stored values. Choose the intended population and evidence requirements before a confirmatory run.

For ΔDecode, an observed event is one remote identity and WSPR cycle with at least one retained report for Target or Reference. A paired event counts once toward its evidence requirement.

Control Default / range Effect
Exclude Special Callsigns Q, 0, 1 Performance on; Benchmark off Excludes remote callsigns beginning with Q, 0 or 1: transmitters in RX, receivers in TX. Target and Reference are exempt. A prefix alone does not identify telemetry.
Exclude Moving Stations Performance on; Benchmark off Excludes peer callsigns reported in more than one grid-4 in the otherwise eligible global reports, before distance filtering. This may reflect movement or incorrect metadata.
Solar state at Target QTH All 24h Keeps all cycles, daylight above +6°, nighttime below −6°, or greyline between those elevations at the Target.
Maximum peer distance from Target (km) Worldwide (≈20 015 km); choices 2 500 / 5 000 / 10 000 / 15 000 km / Worldwide Numeric limits remove peers at or beyond the limit from the analyzed population and exports; Worldwide retains all geographic locations. This changes the analysis, not just the map view. A loaded 20 000 km limit remains available while selected and keeps its original meaning.
Minimum confirmed opportunities per station 1; 1–50 Performance: each station needs at least this many successes plus confirmed misses. Lower values produce coarser rates based on fewer observations. The server-configured corroboration filter also applies to stations with few opportunities; see Section 9.3.1.
Minimum qualifying stations per map segment 5; 1–25 Performance: A segment at or above this minimum shows its Decode Rate color, including 0%. A segment with at least one qualifying station but below the minimum is gray hatched. A segment with no qualifying stations is unfilled.
Minimum qualifying stations per segment for ΔSNR 3; 1–50 The minimum number of stations contributing at least one usable spot pair to the segment after the applicable requirements. A segment also needs an available, non-degenerate pooled-pair CI within the maximum half-width.
Shared confidence level 95%; 70%, 80%, 90%, 95%, 99% In Benchmark, one shared setting governs map and Inspector mean CIs: pooled map pairs, individual stations, pooled Spots, temporal/folded bins and the existing equal-station aggregate. Higher confidence widens an interval with nonzero width for the same data and can change map qualification; it does not change contributing observations or means. In Performance it governs chronological and folded SNR mean CIs at segment and selected-station level, without changing map qualification, counts, means, or the Median/IQR view. Valid custom imported levels are retained.
Maximum ΔSNR map CI (± dB) 0.5; finite positive value Editable numeric map setting: 0.5 means a CI no wider than mean ±0.5 dB. Coloring requires the unrounded pooled-pair CI half-width to be no greater than this value. The station-count requirement remains in force.
Minimum observed stations per segment for ΔDecode 3; 1–50 Count distinct callsign/full-reported-locator identities with at least one retained event in the segment, including one-sided identities. The observed-event share requirement must also be met.
Minimum observed-event share per segment for ΔDecode (%) 1%; 0–5%, steps of 0.5% Benchmark: requires this share of the full filtered run's observed events, rounded up to a whole event. At 0%, every nonempty segment meets this requirement; the observed-station minimum still applies.

For the Benchmark ΔSNR map, the station minimum is three by default, with range 1–50. Coloring additionally requires an available, non-degenerate pooled-pair CI at the shared level, 95% by default, with unrounded half-width no greater than 0.5 dB by default. A half-width of 0.5004 dB fails a 0.5 dB limit, even if a display rounds it to 0.50. The half-width setting changes map qualification and shading only; the confidence setting governs existing mean CIs as well. Neither setting deletes eligible evidence from the Inspector. The compact summary reads CI ± 0.5 dB and Shared confidence level: 95% at the defaults; both values follow the current settings.

The ΔDecode requirement's full-run denominator stays fixed when you crop or select a segment. ΔDecode has no separate per-station event minimum and does not reuse ΔSNR station qualification. Its observed-station minimum and event-share requirement both apply. These requirements describe station breadth and evidence volume, not confidence.

The ΔSNR evidence requirements and ΔDecode evidence requirements appear side by side where screen width permits, with the relevant station minimum first in each section. On narrow screens they stack. Expert Settings follows these requirements and contains Identify ΔSNR outlier candidates and its optional controls.

Benchmark segments with observed evidence but below the relevant threshold are gray hatched; retained station observations remain available. The paired-evidence requirement for ΔSNR does not remove decodes from ΔDecode. In Performance, evidence outside the distance limit may still establish Target activity, without adding those peers to the analyzed population.

Once you manually change either exclusion, that choice persists across Question changes. Stored configurations, demos and analysis links also preserve their explicit exclusions.

11.5 Map, inspector and export controls

These controls let you explore the completed analysis without changing which observations count:

Control Scope and persistence
Segment distance and direction Changes Inspector statistics and time views. Station Insights follows this scope only when its optional segment-and-distance filter is enabled; station metrics and selected evidence retain the full run. Saved separately for Performance and Benchmark.
Filter by selected segment and distance Optionally restricts the Performance or Benchmark station list; otherwise it is global. Selected-station evidence still covers the full run. It sits to the left of the counter-only/one-sided visibility control. This toggle is session-only and is not saved in configurations or shared links.
Station Insights → Filter Restricts the station list and its exported table, not maps or Inspector statistics. Column filters are saved; a station must meet every active condition, while any selected value within one callsign/locator filter can match.
Heard only by other stations. / Only other signals heard. Shows Performance stations with confirmed opportunities but no successful decode. This visibility choice is saved.
Include one-sided evidence Shows Benchmark stations without spot pairs and one-sided Drill-Down observations. This saved visibility choice changes neither coverage totals nor qualification.
Selected station row Saves the exact callsign-plus-locator selection: normally one per result type; multiple Benchmark identities are supported when outlier reporting is enabled.
Time aggregation Changes chronological display bins; Inspector and selected-station choices are saved separately. Pairing, opportunities and fixed one-hour folded bins remain unchanged.
Time basis Selects UTC or Local Solar independently for segment and selected-station plots, with UTC as the new-analysis default at both levels. Each choice applies to that level’s chronological and folded SNR, decode and coverage panels; focused plots follow the selected-station choice. Both choices are saved in configurations, shared analysis links and export metadata. Switching changes the displayed chronological clock while preserving UTC bins and their statistics; folded observations are regrouped before their hourly summaries. Whole-run statistics remain unchanged.
ΔSNR statistic: Median / Mean Benchmark temporal ΔSNR only. Mean is the default for new analyses. Segment and selected-station plots keep independent choices. If a current configuration omits a statistic, that level defaults to Mean; explicit saved choices are honored. The Milazzo demo opens both levels with Median. Median shows the existing median and Bin IQR; Mean shows the arithmetic mean and its available configured pointwise CI. Both preserve eligible observations, bins and pair weighting. Both choices are saved in configurations, shared analysis links and export metadata. Benchmark Statistics, maps, ΔDecode and evidence counts remain unchanged.
Retained Performance SNR-marker setting The optional Performance-only results_view.performance_snr_statistic still accepts mean or median and defaults to mean when omitted. Configurations and shared links retain this compatibility setting. This setting was used by the former successful-SNR histogram. The current Spot & Station Decodes selector uses the independent setting below.
Spot & Station Decodes → Summary statistic (Performance) Selects Mean or Median for the five SNR markers and the bottom-right mean/median station rates by band and over All SNR, and the mean/median station rates in the Stations card. The frequency categories, counts, Spot Decode Rate and Station Reach stay fixed. The optional Performance-only results_view.performance_snr_reach_statistic accepts mean or median, independently of temporal controls. Omission uses mean. Configurations, shared links, restored completed runs and exports retain the selection.
SNR statistic: Median / Mean Performance temporal SNR at both independent levels, default Mean. Both chronological and folded views pool individual successful observations directly. Absolute SNR keeps those values; segment deviations subtract each station's selected run mean or median before pooling individual residuals. Mean shows its configured pointwise CI; Median shows IQR. Absolute density stays unchanged by the toggle; residual density can change with its baseline. Saved configurations, shared links, resumed completed runs and exports retain the selections. Decode Rates, counts, map qualification, the SNR-band summary and fixed station-table medians are unchanged.
Zoom window / Outlier Focus Focuses Drill-Down on an interval for exactly one selected station. Filter table then narrows the displayed rows and the selected Drill-Down table in the download. The focused plots use the full zoom window. Focus and Drill-Down table filters are not saved in configurations or analysis links.

Saved confidence settings. The following fields are useful when inspecting configurations, shared links or exports.

These settings are stored under advanced_parameters and preserved in shared analysis links and export metadata. The independent segment_temporal_statistic and station_temporal_statistic remain under results_view. evidence_confidence_level_percent defaults to 95 and must be strictly between 0 and 100. The corresponding internal ci_alpha = 1 − evidence_confidence_level_percent / 100 specifies the total two-sided tail probability and must be strictly between 0 and 1; the confidence level is 100 × (1 − ci_alpha)%. evidence_confidence_interval_method defaults to iid_student_t. In Benchmark, the same confidence configuration governs individual station means, pooled qualifying-pair means, temporal/folded-bin means, pooled map-pair means and the existing equal-station aggregate for the selected Inspector scope. Each interval uses its own contributing unit and sample SD: pairs for the map and pooled Spots, station means for the Stations aggregate. Benchmark Statistics estimators and populations remain unchanged. The map additionally has its own maximum CI half-width requirement; that threshold does not filter Inspector scope statistics. See Section 9.5.1 for the calculation and assumptions.

In Performance, the same saved confidence fields govern absolute and segment-deviation temporal means described above; each uses individual contributing successful observations or residuals. An omitted temporal statistic defaults to Mean independently at each level, and omitted confidence fields use 95% and iid_student_t. Explicit valid values are honored. These settings change the summaries and their presentation without changing the source-data query or which observations are included. Performance does not gain the Benchmark map CI-half-width threshold.

Saved configurations express the shared confidence setting as advanced_parameters.evidence_confidence_level_percent and advanced_parameters.evidence_confidence_interval_method; the internal ci_alpha remains the corresponding two-sided tail probability. The map limit is stored as advanced_parameters.evidence_max_segment_ci_half_width_db. Saved configurations preserve the effective station-count requirements, shared confidence and map CI limit. An absent half-width uses the default 0.5 dB; an explicitly supplied value must be finite and strictly positive. Invalid values require correction rather than silent replacement.

ΔDecode configuration: Benchmark configuration documents explicitly require settings.advanced_parameters.evidence_min_decode_stations_per_segment, alongside settings.advanced_parameters.evidence_min_decode_event_share_percent. The station minimum is an integer from 1 to 50; new analyses default to 3. Existing installed Benchmark demos explicitly use 1 to preserve their reviewed coloring. Older Benchmark configuration documents missing the required field are rejected rather than silently assigned a new map requirement. Shared links use min_decode_stations_per_segment for this separate ΔDecode setting.

Shared links record the effective Benchmark station minimum explicitly. A link with unresolved, retired or invalid optional parameters restores its recognized valid settings and lists the parameter names that need manual selection before running. Retired names are not aliases and are not silently migrated. Invalid or ambiguous required identity, comparison design or time settings prevent loading. Links load settings only; they do not authorize a new analysis.

Chronological bin choices depend on the complete run duration. A valid saved choice takes precedence over the default and remains available even outside the usual choices below:

Run duration Usual bins Default
Up to 6 hours 2m, 10m, 30m, 1h, 2h, 3h, 6h 10m
More than 6 through 24 hours 2m, 10m, 30m, 1h, 2h, 3h, 6h 30m
More than 24 hours through 7 days 30m, 1h, 2h, 3h, 6h, 12h, 24h 12h
More than 7 days 1h, 2h, 3h, 6h, 12h, 24h 12h

Manual zoom offers Off and the 1h, 3h, 6h, 12h or 24h windows that fit within the completed run. Choose a UTC center or move with Earlier / Later. Outlier Focus includes the event and its surrounding baseline evidence and may exceed 24 hours. The export can include separate focused figures; Section 10.4 defines their scope.

11.6 Benchmark outlier-detection controls

Under Expert Settings, Identify ΔSNR outlier candidates is off by default. Enable it only when investigating temporary departures in paired evidence; see Section 2.5.

Control Default / range Effect
Minimum absolute ΔSNR departure (dB) 6.0; 0.1–100.0 dB Requires a sufficiently large change from the path's local baseline.
Minimum robust z-score 3.0; 0.1–100.0 Also requires the change to be large relative to nearby variation, using the absolute robust score. This score is not a probability.
Maximum pre/post baseline difference (dB) 3.0; 0.1–100.0 dB Requires the baseline medians before and after the candidate to agree within this amount. It does not require low background scatter.

All three requirements, plus the detector's support checks, apply to every event duration. Lowering either minimum or raising the allowed baseline difference makes reporting more permissive. Changing detector settings requires another Run; detections are independent of display-bin width and do not change the ordinary Benchmark maps. Section 9.6 gives the exact method and limits.