12. Troubleshooting and Data Quality
Start with the analysis settings. Lower thresholds cannot repair a wrong callsign or locator, band, time window or transmission schedule.
12.1 Confirm the run definition first
Check the exact Target callsign and QTH, band and UTC window, then actual operation and uploads. For Benchmark, also check Reference identity, common operating times, synchronized clocks and, for TX, schedules and frequency separation. Verify signal routing and actual versus reported power before interpreting an unexpected difference.
12.2 Diagnose by symptom
Read notices against the settings of the completed run. An observed count and a required minimum are different: three observed opportunities do not meet a five-opportunity requirement.
| Symptom | What to check or do |
|---|---|
| No Target/source evidence returned | Check identity, locator, band, UTC window and uploads in the selected database. Review historical mode filtering. Lowering evidence thresholds cannot create source reports. |
| Reports returned, but none remain | Review station exclusions, solar state and maximum peer distance. These may remove the retrieved population. |
| No stations meet the Performance requirements | Compare each station’s confirmed opportunities with the required minimum. Check the filters and the reports used to establish transmitter and receiver activity; unknown activity is not a confirmed miss. |
| Performance stations are available, but no segment is colored | Compare the number of included stations in each segment with its required minimum. Gray hatching (Not qualifying) means at least one station meets the station requirements, but too few remain to color the segment. An unfilled segment (No observations) has no station left for this map after those requirements. A valid 0% Decode Rate is colored; hatching or an unfilled segment does not establish that no reception occurred. |
| Benchmark ΔSNR is missing or hatched | Check for the same remote identities in the same cycles, common operation and synchronized schedules. Then check station pair eligibility and the segment's contributing station count. Select the exact segment in Segment Inspector and compare the pooled Spots mean and ± half-width in the separate Benchmark Statistics section with the selected CI ± limit. The full-precision interval status and qualification reason are in benchmark/map_segments.parquet. A CI may be unavailable, degenerate or wider than the selected limit. With at least two contributing pairs, exactly zero variance across their differences gives a degenerate interval and the segment remains hatched; equal station means alone do not imply zero pair variance. Check paths and dated evidence before changing the requirements. One-sided evidence can still support ΔDecode, and eligible observations in hatched segments remain in Inspector scope statistics. |
| ΔDecode is hatched despite observed reports | Check the segment’s minimum observed-station count and compare its event count with the full-run event-share requirement. Both must be met. Selecting a smaller area does not lower the event-share requirement. |
| Station list is unexpectedly empty | Clear Station Insights column filters and review visibility toggles. In Performance and Benchmark, also check Filter by selected segment and distance. |
| Unexpected ΔSNR sign | Check Target/Reference and physical path assignments, correction sign and power reports. Reconcile an individual pair in Drill-Down. |
| One-sided reports dominate, or no outlier is found | Check operating logs and paired support before, during and after the interval. One-sided reports alone provide no ΔSNR; see activity evidence. |
| Large table has no search or direct CSV download | Above 150 000 displayed rows, read-only tables load while scrolling. Narrow Drill-Down with Filter table, or use the prepared results ZIP. |
| Run exceeds the source row limit, recent reports are missing, or a source fails | Follow upstream-data checks. A smaller map distance does not reduce retrieved rows. |
12.3 Callsign and locator checks
Check identities in the database used by the run, not only in another website's map. Target and Reference selection uses exact callsign plus grid-4; a Target reported at JN37 does not match configured JN38. A manually entered Target map origin is never changed automatically to fit reports. An empty Target locator instead requests discovery before analysis, preserving the selected reported locator's precision.
Reporting tokens must be 3–15 characters; entered Target locators must be valid four- or six-character Maidenhead locators. Reference Grid Locator input uses four characters. Either locator field can remain blank for discovery after Run analysis; the required location must be resolved before the analysis proceeds. Valid syntax does not verify location or operation. Remote identities use the full reported locator, so locator variants can split one physical station into several identities.
WSPRadar neither reconstructs compound callsigns from separate messages nor supplies missing locator fields in database reports. Automatic location discovery uses valid locators already present in reports. See Section 6.1 when a TX identity is missing or incomplete.
12.4 Historical decode-code fallback
WSPRadar normally requests WSPR-2, the two-minute mode, using the database condition code = 1. For a window entirely before 1 January 2022, 00:00 UTC, it retries without that condition if the strict query finds no Target source evidence for Performance, or no source evidence from either setup for Benchmark. A window ending exactly at that boundary or later keeps the strict filter.
This historical fallback broadens selection because older mode records may be incomplete or ambiguous [Ref-8]. Run status and exported decode_filter_mode identify the selection used; they do not establish the physical mode of every historical report. The cutoff is a compatibility rule, not a guarantee of data quality.
12.5 Operating conditions and activity evidence
Benchmark retains eligible paired and one-sided reports without requiring a separate Target-activity witness in each cycle. Even an entire period observed on only one side remains usable as descriptive decode evidence, but provides no ΔSNR. A one-sided interval may reflect reception, schedules, outages or missing uploads; WSPRadar does not identify its cause or remove it automatically. Check logs and use a documented common operating period.
Performance counts each success as its own confirmed opportunity. A miss requires reports establishing activity at both the transmitter and receiver on the same band in the same cycle; otherwise the outcome remains unknown. The direction-specific rules are in Section 9.3.1.
12.6 Working with upstream data
System Audit Status identifies the database and any historical fallback used. Each run uses one source; reports from different databases are not combined. WSPRadar can switch sources for a new attempt, but Reference location discovery ties the ensuing analysis to that source. If it fails, restart and review the newly resolved Reference location. When WSPRadar resolves the Reference location for the run, Complete lists the lookup database and filter, the Reference location used, and the locators reported for that location.
For recent reports, allow about five minutes after the final cycle, then check uploads and availability in the selected database. This is a practical waiting estimate, not a completeness guarantee [Ref-8]. Databases may contain incorrect identities, locators or power values, delayed reports and later corrections. Demo reruns may reuse previously retrieved data, so rerunning need not pick up later corrections.
A request exceeding 1 000 000 complete rows is rejected, not silently truncated. Shorten the UTC window; Exclude Special Callsigns Q, 0, 1 can reduce source queries when appropriate to your question. The distance limit is applied after retrieval, so reducing it does not avoid this limit.